58 User Manual for the Meca500 Industrial Robot (for rmware 10.1)
Table 14: Summary of EMC test results for the Meca500 R3 (continued)
SUMMARY OF TEST RESULTS
Test Name /
Standards
Test specifications
Minimum
performance
criterion
required
Result
Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input
IEC61000-4-11 (2004)
Voltage dips:
0%Un during 1 cycle
40%Un during 10 cycles (at 50Hz)
40%Un during 12 cycles (at 60Hz)
70%Un during 25 cycles (at 50Hz)
70%Un during 30 cycles (at 60Hz)
Short interruptions:
0%Un during 250 cycles(at 50Hz)
0%Un during 300 cycles (at 60Hz)
B
C
C
C
C
C
C
Pass