IF BATTERY CHARGER HAS NO INDICATOR LIGHT LIT NEXT TO CABLE PLUG,
VERIFY BATTERY IS PLACED IN CHARGER PROPERLY.
WHEN CHARGING IS COMPLETE, UNPLUG THE CHARGER CORD FROM THE
POWER OUTLET AND THE BATTERY CHARGER.
PENDANT PRECAUTIONS
CAUTION: Portable and mobile RF communications equipment can affect medical electrical
equipment. This Pendant should not be used adjacent to or stacked with other equipment in
accordance with the directions described in the Practice Reference Manual.
NOTE: EUT (PM750 Pendant) shuts down between +/-8 and 15kV Air Discharge. It is
recommended that you restart the device (wait 30 seconds after power down) upon occurrence
of this event.
WARNING: When using lead wires, they should not contact other conductive equipment or
electric ground, including earth.
Lead failures are detected by a 10 mV peak, 50% duty cycle rectangular pulse, which is
applied to each patient electrode connection through a 4.9Mohm resistor at a rate of 15
Hz with respect to the system ground.
This is a prescribed medical Pendant, not a toy; keep away from small children.
In the event of a damaged Pendant, discontinue use and call Medicomp’s Patient
Support: 877-996-5553, for return and replacement.
ADVERSE REACTIONS
In the event of irritation worse than minor itching from the Electrode Patch or individual
electrodes, consult your physician. Users may also contact Medicomp to discuss alternatives.
Physicians must contact Medicomp to request change of procedure. Medicomp cannot
authorize change of patient procedure.
Signs of significant irritation where the electrode patch is in contact with the skin.
Any other unanticipated reaction to the adhesive or the electrode gel.
MAINTENANCE
Cleaning the TelePatch System
The Universal Pendant
may need to be cleaned if for any reason it becomes exposed to
biological materials, like body fluids or matter. The user should clean the Tele
Patch Monitoring
System in order to maintain optimal use and functionality.
Tele
Patch Cardiac Monitor PM750
USER MANUAL - UTM0000701-05E
| APRIL 4, 2019