258
When you rotate “ ” clockwise, the function code displays the switched parameter number, only RAM modified and
not save to EEPROM.
LED parameter display selection at stop
0: No display
1: Display
Used to set whether a parameter is displayed on the zero level of the keypad menu at stop. Bit0 to bit15 correspond to
16 parameters listed in P16.04.
Note: If all is set to 0, the reference frequency will be displayed.
LED default parameter display at stop
Used to set the default parameter number displayed on the zero level of the keypad menu at stop after power-on.
0: Reference frequency
1: Bus voltage
2: DI input status 1
3: DI input status 2
4: DO output status
5: AI1 input voltage
6: AI2 input voltage
7: AO1 output percentage
8: HDI reference frequency
9: HDO1 output
10: HDO2 output
11: Length
12: Simple PLC current step
13: Line speed
14: PID reference
15: Torque reference