263
2: AI2
3: HDI
4: Modbus
5: PROFINET
P23.02
Torque digital setting
-300.0% to 300.0%
0.0%
The digital setting range of torque reference is -300.0% to 300.0%.
P23.03
Torque reference acceleration/deceleration time
0.0 to 6000.0
6.0 s
Used to set the torque acceleration/deceleration time under torque control. It is invalid under speed control.
Specifies the time the system takes to reach the reference torque from the current torque.
P23.04
FWD speed limit channel
0 to 5
0
P23.05
FWD speed limit digital setting
0.00 Hz to P02.11
0.00 Hz
P23.06
REV speed limit channel
0 to 5
0
P23.07
REV speed limit digital setting
0.00 Hz to P02.11
0.00 Hz
FWD and REV speed limit channels:
0: Digital setting
1: AI1
2: AI2
3: HDI
4: Modbus
5: PROFINET
P23.08 to P23.11
Reserved
For the parameter description, refer to “7.7 P06: Motor 1 torque control parameters”.
7.22 P24: Motor 2 V/F control parameters
P24.00
V/F curve
0 to 5
0
0: Straight-line V/F
1: Multi-point V/F
2: Square V/F