Megmeet MV820 - P40: Fieldbus Option Parameters; P41: IO Option Parameters

Default Icon
323 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
265
P24.17
Stop mode for V/F separation
0 to 1
0
0: Frequency and voltage decline to 0 independently
1: Frequency declines after voltage declines to 0
P24.18
Reserved
P24.19
Reserved
For the parameter description, refer to “7.8 P07: Motor 1 V/F control parameters”.
7.23 P40: Fieldbus option parameters
P40.00
Option type
0 to 3
0
0: No communication options
1: PROFINET option
2: EtherCAT option
3: IO option
Others: Reserved
P40.01
Detection time for options
0.0 to 10.0
0.0 s
P40.02 to P40.33
Reserved
7.24 P41: IO option parameters
P41.00
DI9 function selection
0 to 72
0
P41.01
DI10 function selection
0 to 72
0
P41.02
DI11 function selection
0 to 72
0
For the parameter description, refer to “7.10 P09.03 to P09.10”.
P41.03
Terminal open-circuit voltage
0 to 1
1
0: Digital terminal open-circuit voltage 0 V
1: Digital terminal open-circuit voltage 24 V
P41.04
DI9 to DI11 active mode
0 to 0x111
0
Ones:
0: DI9 positive logic active