288
1. No abnormal heat
generation
1. Within the rated
range and
three-phase
equilibrium
2. Within the rated
range and
three-phase
equilibrium
3. The difference
with ambient
temperature is less
than 35℃
9.2 Periodical maintenance
Users are recommended to carry out periodical maintenance for the drive once every 3 or 6 months based on the
operating environment.
① Only trained professionals are allowed to dismantle, maintain and replace parts of the device;
②
Do not leave any screws, gaskets or other metal things in the machine. Otherwise, the device may be damaged.
General inspection items:
(1) Check if the screws of control terminals are loose. If so, use a screwdriver to fasten them;
(2) Check if the main circuit terminals are poorly contacted, and the connection part of copper bar is overheated;
(3) Check if there is any damage to power cables and control cables, especially whether there is any wear on the cable
sheath;
(4) Check if the insulation tapes around the power cables are stripped;
(5) Clean out the dust on the circuit board and the duct. It is better to use a dust collector;
(6) Before testing the grounding insulating performance of the drive, short all the input and output terminals (L1, L2,
L3/N, U, V, W, BR, +, -) of the main circuit first, and then conduct the grounding test. It is strictly forbidden to conduct