54
Table 4-3 Recommended fuse capacity and copper core insulated wire section
MV820 models
Input line protection
Main circuit (mm
2
)
Control circuit
(mm
2
)
Fuse (A)
Input cable
Output cable
Control terminal
cable
MV820G1-2S0.4B
10
1.0
1.0
0.5
MV820G1-2S0.75B
15
1.5
1.5
0.5
MV820G1-2S1.5B
20
2.5
2.5
0.5
MV820G1-2S2.2B
30
4
4
0.5
MV820G1-2D0.4B
10
1.0/0.75
1.0
0.5
MV820G1-2D0.75B
10
1.5/1.0
1.5
0.5
MV820G1-2D1.5B
20
2.5/1.5
2.5
0.5
MV820G1-2D2.2B
30
4.0/2.5
4.0
0.5
MV820G1-4T0.4B
5
1
1
0.5
MV820G1-4T0.75B
10
1
1
0.5
MV820G1-4T1.5B
10
1.5
1.5
0.5
MV820G1-2T2.2B
30
2.5
4
0.5
MV820G1-4T2.2B
15
1.5
1.5
0.5
MV820G1-4T3.7B
30
2.5
2.5
0.5
MV820G1-2T3.7B
40
6
6
0.5
MV820G1-4T5.5B
40
4
4
0.5
MV820G1-4T7.5B
60
6
6
0.5
MV820G1-2T5.5B
70
6
6
0.5
MV820G1-2T7.5B
70
6
6
0.5
MV820G1-4T11B
70
6
6
0.5
MV820G1-4T15B
70
6
6
0.5

Table of Contents