61
The terminal can only be used as digital
input DI7, and cannot be defined for other
signal functions through function codes.
The terminal can be used as digital input
DI8 or analog input AI1 through the
function code P09.01.
Multi-function
output terminals
Open-collector
output
terminal Y1/
DO1 output
terminal/ HDO1
pulse output
terminal
In addition to being used as
ordinary multi-function
terminals (same as 4, 5, 6,
8, 7, 10, 12, 16), 4 and 5 can
also be programmed as
DO/HDO output terminals.
Refer to P09.00–P09.02 of
7.10 (terminal input
parameters) for specific
terminal selection
(reference point: GND).
For multiple output circuit function
selection, refer to the multi-function
input/output terminal wiring below:
Example:
Maximum operating voltage: 30 V
Maximum output current: 50 mA
Open-collector
output
terminal Y2/
DO2 output
terminal/
HDO2 pulse
output
terminal
The terminal can be
programmed as
multi-function DO or AO.
Refer to P09.02 of 7.10
(terminal input parameters)
for specific terminal
selection (reference point:
GND).
The terminal can be used as digital output
DO3 through the function code P09.02.
Maximum output current: 50 mA
The terminal can also be used as analog
output AO1 through the function code
P09.02. Refer to the AO1 description in the
table.