OILDYNE TRIM PUMP
SERVICE MANUAL NUMBER 28
90-863160 MAY 2000 Page 5A-21
3. Connect the ohmmeter leads to the large terminals on the solenoid.
22493
a
b
d
e
f
c
a-OUT/UP Solenoid
b-12 volt Positive (+) Supply Lead
c-Negative () Supply Lead
d-Ohmmeter Leads
e-BLUE/WHITE Harness Wire Terminal
f-Solenoid Ground Terminal
4. Zero Ohms Reading (Full Continuity)-Solenoid is OK.
High Ohms Reading (No Continuity)-Replace solenoid.
IN/DOWN SOLENOID
1. Connect a 12 volt positive (+) supply lead to the green-white harness wire terminal.
2. Connect the negative () supply lead to the solenoid ground terminal.
3. Connect the ohmmeter leads to the large terminals on the solenoid.
22494
c
d
b
a
e
f
a-IN/DOWN Solenoid
b-12 Volt Positive (+) Supply Lead
c-Negative () Supply Lead
d-Ohmmeter Leads
e-GREEN/WHITE Harness Wire Terminal
f-Solenoid Ground Terminal