Metor 6M PAGE 45
Installation and Operating Manual
92102916 REV 5 9. METAL DETECTION PARAMETERS
SET
FREQUENCY
F1 - F10 F1 Operating frequency setting to inhibit interference
between detectors operating near one another and to
minimize the effect of interference from the environment.
All ten frequencies are applicable to proximity operation.
Set Frequency menu has in addition to number of
manually selected frequencies a frequency search
feature as the first frequency item. Frequency search
does not search for the best frequency but for a
frequency that has a low enough interference level.
SEARCH IN
START-UP
ON/OFF OFF A frequency search is done every time when the
WTMD´s power is turned ON, if this function is enabled.
LO SPEED 1 - 2 2 Speed response setting for slow moving objects.
HI SPEED 1 - 2 1 Speed response setting for fast moving objects.
COPY FROM
METOR =>
REMOTE
Copies the current parameters, excluding the operating
frequency (F1 - F10), into the remote control unit. The
parameters copied into the remote control unit will
remain there until new parameters are copied in their
place. Aim the remote control unit at the display unit until
the WTMD indicates that copying has been completed
successfully (completed ok). The copying will take a few
seconds.
COPY FROM
REMOTE =>
METOR
Copies the parameters from the remote control unit to
the WTMD. The parameters overwrite the current
parameters in the WTMD and are applied immediately.
Aim the remote control unit at the display unit until the
WTMD indicates that copying has been completed
successfully (completed ok). The copying will take a few
seconds.
SAVE CUSTOM
PARAMETERS
Saves the current parameters in the WTMD’s memory.
Saving the parameters will not affect the current
parameters, nor the detection. When parameters are
saved, the operating frequency too is saved. If changes
are made to the current parameters of the WTMD after
the parameters are saved, the saved parameters remain
unchanged.
LOAD CUSTOM
PARAMETERS
Reverts to using the parameters that were saved with
the function ‘save custom parameters’. You can change
the current parameters and use this function to restore
parameters that you have saved earlier. When you
select ‘load parameters’, the saved parameters are
applied immediately.
If no parameters are loaded in the memory, the WTMD
will issue an error message and the parameters applied
before the loading attempt will then remain in force.