PAGE 46 Metor 6M
Installation and Operating Manual
9. METAL DETECTION PARAMETERS 92102916 REV 5
RESTORE
FACTORY
SETTINGS
Resets all the settings back to factory settings.
RND RATE 0 - 100 % 0 %
(RANDOM
ALARM
OFF)
Random alarm rate. The percentage of alarms caused
by the non-alarming people.
RND / ALM
RATE
0 - 100 % 0 % Random alarm rate for normally alarming people. An
extra random alarm is activated for the set percentage of
normally alarming people.
RND TONE 1 - 6 5 The tone used when a random alarm occurs. By default
it is the same as the one used when a natural alarm
(caused by metal items) occurs.
RND VOLUME 0 - 8 2 The volume used when a random alarm occurs. By
default it is the same as the one used when a natural
alarm (caused by metal items) occurs. Random alarm
volume can not be less than what is set by parameter
VOLUME MIN.
RND DISPLAY NORMAL
or
PATTERN
NORMAL If ”NORMAL” is selected (default) display will show
random alarms the same way natural alarms are shown
(off, light bar, counters or alarm rate depending on
2.6 DISPLAY MODE parameter).
If ”PATTERN” is selected display will show a full
”pattern” bar when a random alarm occurs. “Pattern”
bar: <<<<<<<<<<>>>>>>>>>>
CALIBRATION
GUARD
OFF Calibration guard is observing calibration parameters.
When guard is ON and any of the calibration parameters
are changed from saved value a warning message
CALIBRATION CHANGED is shown periodically on
display. The unit operates normally when the calibration
guard is ON.
GUARD MODE ON/OFF OFF Specifies Guard mode operation.
SAVE
CALIBRATION
Saves the changed parameters. Parameters saved as a
calibration parameters are program, sensitivity and
Zone sensitivities.
LOAD
CALIBRATION
Loads saved calibration parameters. If no calibration
parameters has been saved loading is not possible and
a warning message NO CALIBRATION SAVED is
shown.