2.4.4 Protection against electrical shock by means of protective extra-low
voltage (PELV)
All connections and terminals with voltages of up to 50 Volts at the servo drive are protective extra-low
voltage, which are designed safe from contact in correspondence with the following standards:
International: IEC 60364-4-41
European countries within the EU: EN 61800-5-1
DANGER!
High electrical voltages due to wrong connections!
Danger to life, risk of injury due to electrical shock!
Only devices and electrical components and wires with a protective extra low voltage (PELV) may be
connected to connectors and terminals with voltages between 0 to 50 Volts.
Only connect voltages and circuits with protection against dangerous voltages. Such protection may
be achieved by means of isolation transformers, safe optocouplers or battery operation.