EasyManua.ls Logo

Metronix ARS 2100 SE Series - Table 17: ARS 2108 SE: Rated Current for Blocked or Slowly Rotated Motor

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 41
Table 17: ARS 2108 SE: Rated current for blocked or slowly rotated motor (f
el
2 Hz) and
for an ambient temperature of 40 °C
Parameter Values
Power stage clock frequency (kHz)
10
Output current (A
RMS
) 8
Max. output current (A
RMS
) 16 24 32
Max. allowed time (s) 5 0,7 0,2
Power stage clock frequency (kHz) 12
Output current (A
RMS
) 7,4
Max. output current (A
RMS
) 14,8 22,2 29,6
Max. allowed time (s) 5 0,7 0,2
Power stage clock frequency (kHz) 16
Output current (A
RMS
) 6,3
Max. output current (A
RMS
) 12,6 18,9 25,2
Max. allowed time (s) 5 0,7 0,2
Power stage clock frequency (kHz) 19
Output current (A
RMS
) 5,2
Max. output current (A
RMS
) 10,4 15,6 20,8
Max. allowed time (s) 5 0,7 0,2
Product Manual „Servo drives ARS 2100 SE“ Version 5.0

Table of Contents