Manual Corvus-eco
Functions 63
Digital inputs / outputs
For individual controlling tasks Corvus is supplied with an in-
put/output interface with 3 digital inputs and 3 digital outputs.
Input circuit
The input voltage range of the digital inputs is between
0 to 24V.
The inputs are optically isolated but not DC-isolated.
Technical data:
Input voltage Identified as
0 - 2 V
0
3 - 24 V 1
Option
DGND
DGND
Input
0-24V