Covers issues with table power, receptacles, and base operation.
Covers Back, Tilt, and Foot operations and related issues.
Covers Home function and Rotational Base Brake issues.
Defines LED states (On Continuously, Slow Flashing, Fast Flashing, OFF) and their meanings.
Steps to test and identify issues with wired hand and foot controls.
Guide for testing the hand/foot control PC board and its LEDs.
Checks for single beeps, no response, and LED status.
Steps to re-associate wireless controllers with the table.
Shows placement of Treatment Pan, Seat, Foot Extension, and Foot switches.
Explains base actuator components and troubleshooting for motor issues.
Procedure to override Overtravel limit switches for base operation.
Explains back actuator components and troubleshooting for motor issues.
Procedure for testing the back actuator's movement capability.
Explains tilt actuator components and troubleshooting for motor issues.
Procedure for testing the tilt actuator's movement capability.
Method for measuring tilt actuator motor resistance to check for defects.
Explains foot actuator components and troubleshooting for motor issues.
Procedure for testing the foot actuator's movement capability.
Method for measuring foot actuator motor resistance to check for defects.
Describes how the power toroid supplies voltage to various components.
Details the power supply from the PC board to the motor control hub.
Explains how to override Overtravel limit switches for base, tilt, and back functions.
Steps required to calibrate the table after component replacement or adjustment.
Method for enabling or disabling control lockout for safety.
Describes the safety feature preventing movement near the floor or obstructions.
Procedures for accessing brake pedal switches and related components.
Covers screwdriver tests, magnet adjustments, and PCB tests for the brake.
Steps for safely separating the upper and lower base castings for service.
Procedures for removing, installing, and raising base shrouds and cladding.
Steps for removing and reinstalling the base cover.
Guide for accessing and removing foot smart sensor switches.