113
Periodic checks
The machine should be serviced every 1000 hours of operation, or
at least once a year by Miele Service.
This maintenance will cover the following:
Electrical safety according to national regulations (VDE 0701/0702
in Germany)
Door mechanism and door seal
Any screw connections and connectors in the wash cabinet
Water inlet and drainage
Internal and external dispensing systems
Spray arms
Filter combination
Sump including drain pump and non-return valve
All mobile units, baskets, modules and inserts
Steam condenser
Wash pressure sensor
Drying unit
Conductivity meter
If there is a communication module:
Any printer connected to the machine
Network connection
External documentation software and the computer network will
not be tested by Miele.
The following operational tests will be carried out within the
framework of the maintenance:
A programme will be run as a test run
Thermo-electrical measurements will be taken
Seals will be tested for water tightness
All relevant measuring systems will be safety tested including error
message displays
Safety features