Plumbing
153
The inlet hose is approx. 1.7m long terminating in a ¾" female
thread. On no account may the inlet filter be removed.
Install the filter (supplied in accessory pack) between the stopcock
valve and the inlet hose. The filter for AD water is made of
chromium-nickel steel and can be recognised by its dull surface.
IMPORTANT
UK, Australia and New Zealand
For the UK, Australia and New Zealand a non-return check valve is
required between the tap and filter.
Do NOT shorten or otherwise damage the inlet hoses (see
diagram).
See installation diagram supplied.