Chapter 5 Dealing with Problems
121
Message Cause Corrective action
Clean the media sensor. "Media
Sensor Cleaning"(P. 98)
Please load media. No media is loaded, or the
sensors are faulty.
Load the media. "Loading the
Media"(P. 51)
No media detected The media width has not
been detected.
Detect the media width. "Loading
the Media"(P. 51)
Replace Wiper The wiping count
exceeded the preset
value.
Replace the wiper, then reset the count.
"Wiper Replacement"(P. 103)
Wiper Move Failure The wiper is not operating
correctly.
1. Clean the wiper and around the wiper.
"Wiper Cleaning"(P. 92)
2. Turn off the power on the machine and turn
it on after a while. "Turning Off the
Power"(P. 31)
Replace Waste ink tank The waste ink tank count
exceeded the preset
value (90%).
Automatic maintenance is not possible
while the covers are open. Perform the
following steps:
1. Check the waste ink levels in the waste ink
tank. "When “Check Waste Ink Tank”
message appears"(P. 113)
2. Replace the waste ink tank, then reset the
waste ink level. "Replacing the Waste
Ink Tank"(P. 113)
Check Waste Ink Tank The waste ink tank count
exceeded the preset
value (80%).
1. Check the waste ink levels in the waste ink
tank. "When “Check Waste Ink Tank”
message appears"(P. 113)
2. Replace the waste ink tank, then reset the
waste ink level. "Replacing the Waste
Ink Tank"(P. 113)
No washing liquid cartridge No maintenance liquid
cartridge is loaded.
Load the maintenance liquid cartridge.
Replace the washing liquid
cartridge
The maintenance liquid
has run out.
Replace with a new maintenance liquid
cartridge.
Washing liquid end The maintenance liquid
has run out.
Replace with a new maintenance liquid
cartridge.
High ambient temp. ** C Ambient temperatures are
too high.
Adjust ambient temperatures to
temperatures within the specified range.
Optimum print quality may not be
possible unless ambient conditions are
within the specified range.
"Installation Precautions"(P. 14)
Low ambient temp. ** C Ambient temperatures are
too low.
Auto-correction failed White media is not used.
The media is dirty.
The media lifts up.
There is dirt around the
sensor.
Load white and clean media.
Load media so it does not lift up.
Clean the area around the sensor.
"Automatic Correction Sensor (DAS)
Cleaning"(P. 97)
If automatic correction fails repeatedly,
correct the position manually. [MENU] >
[Setup] > [Feed Comp.] or
[Drop.PosCorrect]