EasyManua.ls Logo

MIMAKI jV100-160 - Setting Heater Temperatures

MIMAKI jV100-160
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Printing
57
2.4 Setting the Heater Temperature
Adjust the temperature setting to suit the type of media used. The temperature can be altered while printing
is in progress, but this may cause color variations to occur.
The temperature setting in the RIP software takes precedence. If you are using the Mimaki RIP
software (RasterLink), the recommended values are stored in the color profile.
Adjust the heater temperature to suit the media type and characteristics. Depending on the type,
the media may expand or shrink or become rippled.
1
On the LOCAL mode screen, select [HEATER].
The Heater Temperature Setup screen appears.
2
Enter the heater temperatures, then press the [ENTER] key.
Printing is possible once the heater temperatures reach the temperature settings ±3 °C.
Name Outline
PRE (Pre-heater) Preheats the media before printing to suppress rapid temperature
change.
PRINT (Print heater) Helps prevent ink bleeding.
POST (Post-heater) Allows ink to dry after printing.
2

Table of Contents

Other manuals for MIMAKI jV100-160

Related product manuals