Chapter 5 Dealing with Problems
129
Error
number
Message Cause Corrective action
b1b BaseIO PCB Vpow-s • A problem was detected
with the Base IO PCB
power supply.
• Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 31)
b1c BaseIO PCB V24
b1d BaseIO PCB V24-A
b21 SLIDER1 PCB V3R3 • A problem was detected
with the slider PCB power
supply.
• Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 31)
b22 SLIDER1 PCB V2R5
b23 SLIDER1 PCB V1R8
b24 SLIDER1 PCB V1R2
d09 HD MEMORY [1234] • A problem was detected
with head internal
memory.
• Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 31)
SYSTEM HALT
Error
number
Message Corrective action
406 WIPER ORG
1. Clean the wiper and around the wiper.
"Wiper Cleaning"(P. 92)
2. Turn off the power on the machine and turn it on after a while.
"Turning Off the Power"(P. 31)
• If any other SYSTEM HALT number is displayed, Turn off the power on the machine and turn it
on after a while. "Turning Off the Power"(P. 31)