EasyManua.ls Logo

MIMAKI jV100-160 - About the Relay Box

MIMAKI jV100-160
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Appendix
135
6.2 About the Relay Box
A fire may occur if another manufacturer’s external drying heater is used. Be sure to connect to
the machine via the specified optional compact relay box or the relay box 2.
The JV100-160 allows only one relay box (OPT-J0370 or OPT-J0407) to be connected.
The optional connection relay cable (OPT-J0512 drying fan connection kit) is required when
using a relay box.
l
Outline
The relay box switches the heater power on and off automatically linked to the machine operation.
The heater power is shut off if printing stops to prevent heating while no operation is in progress.
The relay box does not have the temperature control function of the external drying heater. Set the
temperature on the external drying heater side.
l
Specifications
Compact relay box (OPT-J0370) Power
supply
specificatio
ns
Single-phase 100 to 120 V AC/12 A, single-phase 200
to 240 V AC/8 A, 50/60 Hz, single-circuit supply from
main power supply
Type Electric heater using resistance heater, or lamp
Relay box 2 (OPT-J0407) Power
supply
specificatio
ns
Single-phase 100 V to 240 V AC/30 A, 50/60 Hz, single-
circuit main power supply
Type Electric heater using resistance heater, or lamp
6