Chapter 2 Basic Operation
2-4
Cautions about Turning the Power OFF
Do not turn the main power switch OFF.
When the main power switch is ON, the power
periodically turns ON and the operation for preventing
ink sedimentation is carried out.
When the main power switch has been turned OFF,
the function for preventing ink sedimentation will not
work, and this may cause nozzle clogging.
Keep the front cover and the maintenance
cover closed.
If the cover is opened, the function for preventing ink
sedimentation does not work.
Turn the power OFF after having checked the
position of the head.
If the power is turned OFF in a state where the head
has not returned to the capping station, the ink head
dries, which may cause nozzle clogging.
In this case, turn the power ON again and check that
the head has returned to the capping station, and then
turn the power OFF.
Do not turn the power OFF during printing.
The head may not return to the capping station.
After having turned the power switch OFF by
pressing [END/POWER] key, turn the main
power switch OFF.
When turning the main power switch off for moving the
machine or for solving the error or the like, press the
[END/POWER] key a long time on the front of the
machine, check the display is turned off on the
operation panel, and then turn the main power switch
off.
Setting the media
1
Setting the media thickness.
(1) Press the [FUNC1] (MENU) [] (1 time)
[ENTER] key in LOCAL.
(2) Select “MEDIA THICKNESS”, and press the
[ENTER] key.
(3) Press [][] to set the media thickness, and
press the [ENTER] key.
Setting the Table Height
If the table height is changed, Media Thickness is also
changed.
1
Press the
(MENU)
in LOCAL.
2
Press to serect “HEAD
HEIGHT” , and press the key.
HEAD HEiGHT MENU will be displayed.
3
Press to serect “TABLE
HEIGHT” , and press the key.
4
Press to set the table height,
and press the key.
Set value : 0.0 to 153.0mm
5
Press the key several times to
end the setting.
The peripheral parts of the media could roll up due
to heat. Fix the media supplementarily using
adhesive tapes, etc.
When using a jig, enter the jig's height + the media
thickness.
Place the media so that concentrated load is
prevented.
The value to be entered varies by the number of
table spacer.