5-2 Mx-Series Manual
1001
Fail to read data
from the message
queue (Contact the
MRC.)
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
1002
Could not create task
(Contact the MRC.)
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
1003
The emergency button
is pressed.
Restore the emergency switch to
original position and retry. If the
error occurs repeatedly, check the
EMG signal line following the EMG
signal line check procedure.
5-26
1004 - 1020
(Main) Motion board
failure
(No response)
Power on 10 sec after machine
power off and check again.
If the error is not resolved, replace
the motion board.
5-31
1021
Do not push gantry. The
(Main) Z-axis could
collide with the conveyor
guide.
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
1022
The Y-axis servo motor
failed to power on as all
of the (Main) gantries
are beyond the safety
limit.
Applied to the Mx Series Dual
Gantry. Let the gantries enter the
safety limit and check again.
1023
Power Box Over-
Temperature Failure
Check the power box.
(Not applicable to Mx Series)
5-42
1024
Power Box Input
Voltage Failure
Check the power box.
(Not applicable to Mx Series)
5-43
1025
Power Box Over or
Under Voltage Failure
Check the power box.
(Not applicable to Mx Series)
5-44
1026
UPS Battery Low
(Not applicable to Mx Series)
5-42
2000 2037
Motion board error
(Library)
Unidentifiable error. Power on 10
sec after machine power off and
check again (MEI).
5-31
Error
Code
Message Description
Actions
References
3000 -
3039
The servo motor
power is Off.
(Front X axis, Front Y1
axis)
Press the Servo On switch and try
again. If the error occurs repeatedly,
check according to the check
procedure.
3040
The axis failed to
move to the set
position (Front Xaxis)
Try again. If the error occurs
repeatedly, contact the C/S engineer
to adjust the gain.
5-34

Table of Contents