5-6 Mx-Series Manual
4038
STX error
(Port 5 - intelligent
feeder)
Not applicable to Mx Series
4039 -
4041
STX error
(Port 6 - Reserved1)
Unidentifiable error. Ignore and
continue. If the error is not resolved,
check again after power Off/On. If the
same error occurs repeatedly, contact
the C/S engineer.
4042
Data not received
(Port 1 - T-Box)
Check the T-Box and the T-Box cable
connection. If there is no error, check
the board port and alpha program.
4043
Data not received
(Port 2 - Front VSC)
Not applicable to Mx Series
4044
Data not received
(Port 3 - Rear VSC)
Not applicable to Mx Series
Error
Code
Message Description
Actions
References
4045 -
4048
Data not received
(Port 4 - TSU)
Unidentifiable error. Ignore and
continue. If the error is not
resolved, check again after power
Off/On. If the same error occurs
repeatedly, contact the C/S
engineer.
4049
LRC not received
(Port 0 - Serial Shell)
Unidentifiable error. Ignore and
continue. If there is no defect,
check again after power Off/On. If
the same error occurs repeatedly,
contact the C/S engineer.
4050
LRC not received
(Port 1 - T-Box)
Check the T-Box and the T-Box
cable connection. If there is no
defect, check the board port and
alpha program.
4051-
4053
LRC not received
(Port 2 - Front VSC)
Not applicable to Mx Series
4054
LRC not received
(Port 5 - intelligent
feeder)
Not applicable to Mx Series
4055 -
4056
LRC not received
(Port 6 -
Reserved1)
Unidentifiable error. Ignore and
continue. If the error is not
resolved, check again after power
Off/On. If the same error occurs
repeatedly, contact the C/S
engineer.
5000
VSC board
communication fail
Not applicable to Mx Series
5-30
5001
The VSC board is not
ready to communicate.
Not applicable to Mx Series
5-30

Table of Contents