Device menu
59
During the pre-alarm phase, the alarm can be cancelled:
• For the Mandown alarm: Press Esc or hold the handset in the vertical position for at
least 4 seconds.
• For the Escape alarm: Press Esc.
• For the No movement alarm: Press Esc or shake the device sideways for 1-2
seconds.
Mandown
Use Change
to switch the Mandown alarm on and off.
Alarm in
conversation
Switch off this feature to prevent alarm activation by mistake
during an active call.
Delay Allows you to set the amount of time the DECT phone can
remain outside the vertical position before a pre-alarm is
triggered (1-75 seconds).
Switch Vibra call off in the Ringer settings (see “Profiles menu”
on page 61) if you wish to use the Mandown alarm.
Angle Select the inclination angle of the DECT phone in which the
alarm will be triggered.
Steep: Approximately 45° from the vertical position.
Medium: Approximately 55° from the vertical position.
Flat: Approximately 65° from the vertical position.
The inclination angle will be detected in each axis of the DECT
phone.
No movement alarm
Use Change to switch the no movement alarm on and off.
Alarm in
conversation
Switch off this feature to prevent alarm activation by mistake
during an active call.
Delay Allows you to set the amount of time the handset can remain
still before a pre-alarm is triggered (1-75 seconds). To prevent
unwanted alarms, pressing any key on the device resets the
delay, e.g. if you are navigating the menu.
Sensibility Allows you to set the sensitivity (low, medium, high). This
allows you to adapt the sensor to the different movements (e.g.
ways of walking) of the surveillance personnel:
• Low sensibility means: Slow movements are enough to
reset the delay once again.
• High sensibility means: Only rapid (jolting) movements will
reset the delay.
Switch Vibra call off in the Ringer settings (see “Profiles menu” on page 61) if you wish
to use the no movement alarm.
Escape alarm
Use Change to switch the escape alarm on and off.
Alarm in
conversation
Switch off this feature to prevent alarm activation by mistake
during an active call.
Delay Allows you to set the amount of time the handset can be in
rapid movement before a pre-alarm is triggered (1-75
seconds).