EasyManua.ls Logo

Mitsubishi Electric CR800-D Series - Startup and Initial Settings; Restart the Robot Controller; Check Predictive Maintenance Function Enabled

Mitsubishi Electric CR800-D Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Startup and initial settings 33
Restart the robot controller.
5
R
e
s
t
a
r
t
t
h
e
r
1) Turn off the switch of the earth leakage circuit breaker.
2) Turn on the switch of the earth leakage circuit breaker.
1) Turns off the power of the robot CPU system.
2) Turn off the switch of the earth leakage circuit breaker.
3) Turn on the switch of the earth leakage circuit breaker.
4) After the POWER lamp of the robot controller lights, turn on the power of the robot
CPU system.
CR800-D type
CR800-R/Q type
Check that the predictive maintenance function is enabled.
6
1) When the MELFA Smart Plus card is used, the LED of the MELFA Smart Plus card flashes green.
When the MELFA Smart Plus card pack is used, the LED flashes blue.
2) Check that the predictive maintenance function has been enabled.
• For the teaching pendant
Check that the "MSPPMENB" parameter is set to [1].
• For RT ToolBox3
Connect RT ToolBox3 to the robot controller and start a project from "Online"
Click [Online] - [Maintenance] to expand the project tree and check that "Predictive
Maintenance" is displayed.
RT ToolBox3
project tree
Maintenance
Predictive Maintenance