150
9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
The settings of "Clock" of two 16-bit counter timer blocks must be the same. When one "Clock" setting is
changed, the other "Clock" setting is changed automatically.
The following table shows "User Address" used for the parameters.
Output
The following table shows the output of the counter timer block.
*1 The valid range is determined by the type of the multi function counter block arranged in the hardware logic outline window.
*2 The cam switch block can be linked only when a 32-bit counter timer block is used. The 32-bit counter timer block and the cam switch
block are linked automatically and the link cannot be deleted.
*3 Counter timer blocks and Comparison blocks are linked automatically in the following combinations, and the links cannot be deleted.
"Count Value" terminal of "Counter_Timer_0" and "Input" terminal of "Compare_0"
"Count Value" terminal of "Counter_Timer_1" and "Input" terminal of "Compare_1" (This combination cannot be used for 32-bit multi
function counter blocks.)
The count value is cleared to 0 when the hardware logic control is stopped.
To stop the count operation without clearing the count value, set "Count Enable" to "OFF". To switch the on/off
of "Count Enable" during the hardware logic control, assign a buffer memory address to "User Address" of
"Count Enable".
Variable name Data type Valid range Setting range Description
User Address Word 1000 to 1099 Only even addresses can be assigned to the
parameters of two words (32 bits).
Variable name Data type Linkable block Output value Description
Count Value Word Comparison
*3
Cam switch
*2
-32768 to 32767 (16-bit signed
counter)
*1
0 to 65535 (16-bit unsigned
counter)
*1
-2147483648 to 2147483647
(32-bit signed counter)
*1
0 to 4294967295 (32-bit
unsigned counter)
*1
Outputs the value counted by the counter
timer.