10 BLOCK LINK EXAMPLES
10.1 Coincidence Detection
177
10
Precautions for using 16-bit multi function counter blocks
Coincidence detection control can be set even with 16-bit multi function counter blocks. However, usable blocks are different.
The following shows link examples of the hardware logic outline window and multi function counter block detail window.
Hardware logic outline window
Multi function counter block _0 detail window (coincidence detection)
Create the hardware logic by using compare blocks and a set/reset block, as shown in the dotted line frame.
IN 0
IN 1
OUT 0
Input 0
Input 1
Output 0
SI 0
Multi function
counter block_0
(coincidence
detection)
Input 0
Count Value
Output 0
Input 1
UP
DOWN
Compare 0
Set/reset
Counter timer
Input signal
event detection
block
Condition: Coincidence
Compare Mode A: =
Compare Mode B: <>