477
FX3G/FX3U/FX3GC/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
17 Data Transfer 2 – FNC100 to FNC109
17.2 FNC103 – ZPOP/Batch POP of Index Register
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High-Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
17.2 FNC103 – ZPOP/Batch POP of Index Register
Outline
This instruction restores the contents of the index registers V0 to V7 and Z0 to Z8 which were batch-stored temporarily
by ZPUSH (FNC102) instruction.
For ZPUSH (FNC102) instruction, refer to Section 17.1.
1. Instruction format
2. Set data
3. Applicable devices
S: Except special data register (D)
Explanation of function and operation
1. 16-bit operation (ZPOP/ZPOPP)
For the function and operation, refer also to Section 17.1.
1) The contents of the index registers V0 to V7 and Z0 to Z7 which were batch-stored temporarily to and later
are restored to the original index registers. When the contents of the index registers are restored, the number of
times of batch-storage is decremented by "1".
2) For temporarily batch-storing the data, use ZPUSH (FNC102) instruction.
Use ZPUSH (FNC102) and ZPOP (FNC103) instruction as a pair.
Related instruction
Errors
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is stored in
D8067.
When the number of times of batch-storage (D) stores "0" or a negative value while ZPOP (FNC103) instruction is
executed (error code: K6706)
Program example
For a program example, refer to Section 17.1.
Operand Type Description Data Type
Head device number temporarily batch-storing the contents of the index registers V0 to V7
and Z0 to Z7
: Number of times of batch-storage
+1 to +16 × Number of times of batch-storage: Batch-stored data storage
destination
16-bit binary
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
V Z Modify K H E "
"P
S
3
Instruction Description
ZPUSH(FNC102) Temporarily batch-stores the present value of the index registers V0 to V7 and Z0 to Z7.
P
FNC 103
ZPOP
16-bit Instruction
3 steps
ZPOP
ZPOPP
Continuous
Operation
Pulse (Single)
Operation
Mnemonic Operation Condition Mnemonic Operation Condition
32-bit Instruction
D
D
D D
D
Command
input
FNC103
ZPOP
D
D
D

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
ModelFX3U Series
Program Memory64k steps
Execution Speed0.065 μs/basic instruction
TypePLC (Programmable Logic Controller)
Power Supply100-240V AC
I/O PointsUp to 384
CommunicationUSB
ExpansionSupported via expansion modules
High-Speed CountersUp to 6 channels
Analog Input/OutputAvailable via expansion modules
Temperature Range0 to 55°C
Programming LanguageLadder Logic, Structured Text
Built-in FunctionsPID control
Humidity5 to 95% (non-condensing)

Related product manuals