890
FX3G/FX3U/FX3GC/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
Appendix A-1-2 Cautions on writing during RUN
"In the FX3G, FX3U, FX3GC and FX3UC PLCs, writing is enabled during RUN (program changes during RUN mode)
using the following programming tools."
For the operating procedure of and cautions on writing during RUN,
refer to the respective programming tool manual.
Programming tools which support writing during RUN
Japanese version
*1. Write during RUN is not possible with a SFC program.
*2. Write during RUN is not possible with a list program or a SFC program.
Programming tool PLC Version Remarks
GX Works2
*1
(SWDNC-GXW2-J)
FX3G/FX3GC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs earlier than Ver. 1.40.
Ver. 1.77F or later
Writing in the instruction and device ranges during RUN is supported in FX3G
and FX3GC PLCs earlier than Ver. 1.40.
FX3U/FX3UC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.70.
Ver. 1.45X or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.70.
GX Developer
*2
(SWD5C-GPPW-J)
FX3G
Ver. 2.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 1.00.
Ver. 5.00A or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLC Ver. 1.00.
Ver. 8.72A or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLC earlier than Ver. 1.10.
Ver. 8.76E or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLC Ver. 1.10.
FX3U/FX3UC
Ver. 7.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 3.00.
Ver. 8.13P or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLC earlier than Ver. 1.30.
Ver. 8.18U or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLC earlier than Ver. 2.20.
Ver. 8.23Z or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.30.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.61.
Ver. 8.82L or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.61.
FX-PCS/WIN
*2
FX3G Ver. 4.00 or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLC Ver. 1.00.
FX3U/FX3UC
Ver. 1.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2 PLC
Ver. 3.30.
Ver. 2.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 1.00.
Ver. 4.20 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 3.00.

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals