481
FX3G/FX3U/FX3GC/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
18 Floating Point – FNC110 to FNC139
18.2 FNC111 – EZCP / Floating Point Zone Compare
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High-Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
18.2 FNC111 – EZCP / Floating Point Zone Compare
Outline
This instruction compares data (binary floating point) with two values (one zone), and outputs the comparison result to
three consecutive bit devices.
For handling of floating point, refer to Subsection 5.1.3.
1. Instruction format
2. Set data
*1. When a constant (K or H) is specified, it is automatically converted from binary into binary floating point (real
number) when the instruction is executed.
3. Applicable devices
S: "D.b" cannot be indexed with index registers (V and Z).
Operand Type Description Data Type
Data register number storing binary floating point data to be compared
Real number (binary)
*1
Data register number storing binary floating point data to be compared
Data register number storing binary floating point data to be compared
Head bit device number to which the comparison result is output (Three devices are
occupied.)
Bit
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
V Z Modify K H E "
"P
33 3 3 33 3
33 3 3 33 3
33 3 3 33 3
33 3 S 3
P
FNC 111
EZCP
D
Mnemonic Operation Condition
16-bit Instruction
DEZCP
DEZCPP
Mnemonic Operation Condition
32-bit Instruction
17 steps
Continuous
Operation
Pulse (Single)
Operation
S
1
S
2
S
D
S
1
S
2
S
D

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals