20 Positioning Control – FNC150 to FNC159
20.2 FNC151 – DVIT / Interrupt Positioning
S2 : When using a special high-speed output adapter for the pulse output destination in an FX3U PLC, the rotation
direction signal must be used by the following table output.
When using a built-in transistor output for the pulse output destination in an FX
3U/FX3UC PLC, the rotation
direction signal must use transistor output.
S3:"D.b" cannot be indexed with index registers (V and Z).
Explanation of function and operation
Caution on writing during RUN
During RUN, avoid writing while the DVIT (FNC151) instruction is executed (that is, while a pulse is output).
Note that if writing is executed during RUN to a circuit block including the FNC151 instruction while pulses are output,
the PLC decelerates and stops pulse output.
Function change depending on the version
The functions of FNC151 instruction are changed depending on the version as shown in the table below.
For explanation of the instruction and the contents of function change,
refer to the Positioning Control Edition.
Special high-speed output adapter No. Pulse output Rotation direction output
No. 1 (1st unit)
=Y000
=Y004
=Y001
=Y005
No. 2 (2nd unit)
=Y002
=Y006
=Y003
=Y007
Applicable version
Item Outline of function
FX3U FX3UC
Ver. 2.20 or later Ver. 1.30 or later
Interrupt input signal
specification function
When M8336 is set to ON, the interrupt input signal corresponding to Y000
to Y003 is changed to an input number (X000 to X007) specified by D8336.
When using a transistor output in the main unit, Y003 cannot be specified.
Ver. 2.20 or later Ver. 2.20 or later User interrupt mode
When "8" is specified by D8336 to the interrupt input signal corresponding
to Y000 to Y003 and M8336 is set to ON, the interrupt input signal is
changed to a special auxiliary relay. When this changed special auxiliary
relay is set to from OFF to ON in an input interrupt program, the PLC starts
the interrupt operation. When this function is used, however, the logic of
the interrupt input cannot be inverted.
In addition, when using a transistor output in the main unit, Y003 cannot be
specified.
D
1
D
2
D
1
D
2
D
1
D
2
D
1
D
2
Command
input
FNC151
DVIT
S
2
S
1
D
1
D
2

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals