610
FX3G/FX3U/FX3GC/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
26 Character String Control – FNC200 to FNC209
26.1 FNC200 – STR / BIN to Character String Conversion
When the devices and later storing a character string exceeds the corresponding device range (error code:
K6706)
Program example
In the program below, the 16-bit binary data stored in D10 is converted into a character string in accordance with the
digit specification by D0 and D1 when X000 is set to ON, and then stored in D20 to D23.
D
X000
Data to be converted is set.
FNC 12
MOVP
K12672 D10
END
K6 D0
K0 D1
FNC200
STRP
D0 D10 D20
FNC 12
MOVP
FNC 12
MOVP
The number of all digits is set.
The number of digits of the decimal
part is set.
12672
6
0
b15 b8 b7 b0
D20
D21
D22
31H(1)
36H(6)
0000H
20H(space)
32H(2)
32H(2) 37H(7)
D23
D10
D0
D1
Number of all digits
Number of digits of
decimal part
16-bit binary data "
12672"

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
ModelFX3U Series
Program Memory64k steps
Execution Speed0.065 μs/basic instruction
TypePLC (Programmable Logic Controller)
Power Supply100-240V AC
I/O PointsUp to 384
CommunicationUSB
ExpansionSupported via expansion modules
High-Speed CountersUp to 6 channels
Analog Input/OutputAvailable via expansion modules
Temperature Range0 to 55°C
Programming LanguageLadder Logic, Structured Text
Built-in FunctionsPID control
Humidity5 to 95% (non-condensing)