48
No. 99MBC139A
4 Data Output
■ Output signals
●
ALLGO
Tips
When both 3-step tolerance judgment and 5-step tolerance are selected, the range in which channels are
GOis"S1≤measurementresult≤S4".
When using multiple EJ Counters that are linked together, the tolerance judgment will be handled as "GO" for
any EJ Counter for which tolerance judgment is set to "None" (Parameter Number 8 is set to 2).
Tolerance unacceptable on one or
more axes (ERR).
Max. 10 msMax. 100 ms
Tolerance OK (GO)
on all axes.
ALLGO
3-step tolerance value setting 5-step tolerance value setting
Judgment conditions
ERR/GO
Judgment
Judgment conditions
ERR/GO
Judgment
Measurement result < S1 ERR Measurement result < S1 ERR
S1≤measurementresult≤S4 GO S1≤measurementresult<S2 GO
S4 < measurement result ERR S2≤measurementresult≤S3 GO
S3<measurementresult≤S4 GO
S4 < measurement result ERR
●
Error output
Tips
For details about error message contents, see "5.2 Error Messages" on page 52.
Error occurs
Max. 100 ms Max. 10 ms
Error canceled
ERR
LT1
LT2
LT3

Related product manuals