49
No. 99MBC139A
4 Data Output
4.2 Data Input/Output
External data input/output is possible through the optional interface unit.
Data that can be input/output through interface units are as follows.
Interface unit Format
Possible data I/O
Output Input
USB
(Part No. 21HZA149)
USB2.0 FS
(12 Mbps)
Current value (by channel)
Preset value (by channel)
Tolerance value (by channel)
Errors
(by channel and by counter)
Parameter setting values
(by counter)
Number of counters con-
nected
Counter ID
Preset value (by channel)
Tolerance value (by channel)
Peak mode selection
(by channel)
Preset and zero set
(by channel)
HOLD set/clear
(by counter )
Peak clear
(by counter)
Error clear
(by counter)
Parameter settings
(by counter)
CC-Link
(Part No. 21HZA186)
CC-Link
V1.10
Tolerance judgment result
(by channel, All)
Gage connection status
CC-Link
V2.00
Current value data
(by channel)
Tolerance judgment result
(by channel, All)
Gage connection status
USB2.0 FS
(12 Mbps)
Current value (by channel)
Preset value (by channel)
Tolerance value (by channel)
Errors
(by channel and by counter)
Parameter setting values
(by counter)
Number of counters con-
nected
Counter ID
Preset value (by channel)
Tolerance value (by channel)
Peak mode selection
(by channel)
Preset and zero set
(by channel)
HOLD set/clear
(by counter)
Peak clear
(by counter)
Error clear
(by counter)
Parameter settings
(by counter)