No. 99MAH040B
2 SETUP
This chapter describes installation of a battery, adjusting display
angle and mounting on the bore gage
2.1 Installation (replacement) of Battery and Initial
Setting
A lithium battery (CR2032) is used with this instrument.
This instrument is not delivered with the battery set into position, so set the battery before
use.
1. Remove the battery holder by using a flat-blade screwdriver or the like.
(When replacing the battery, remove the spent battery.)
2. Set the battery into the battery holder as described in the figure below.
3. Set the battery holder into the original position. ([------] is displayed.)
4. To enter into the preset setting, press the center key.
5. Set up the preset values referring to "3.2.1 Preset setting".
6. Set up measurement mode and function which you want. (See section 3. Functions
and Operating Procedure.)