No. 99MAH040B
3.2.3 Changing to minimum value detection mode
Press the center key to change the minimum value detection mode. It can to hold the
minimum values of the measured values fluctuate.
When the measurement value is below the minimum value is retained a new minimum
value, and then held until the center key is pressed. Press the center key to restart
minimum value measurement.
When Power OFF, Setup mode transition, preset setting, and data load is performed, the
minimum value detection mode is canceled, and change to normal mode.
・ Please start measuring while the contact point is contacting the measuring target.
・ Note that the displacement caused by vibration, impact, etc. is detected.
・ Holding and saving the display value is possible in the minimum value detection mode.
(Refer to "3.2.4 Holding display value", “3.2.6 Data save/Data load)
・ The minimum point can be edited into a desired value. So this instrument can measure
based on this point. Refer to "3.2.1 Preset setting" to set the preset.
・ When a minimum value pointer of the analog bar is out of displayable range, the
pointer automatically moves to the center by selecting the “Auto”.
3.2.4 Holding display value (when a data processor is not connected)
Press the lower right key in the measurement mode. "H" is displayed and the display value
will be held. Press the lower right key again to release the hold.
・ If a data processor is connecting to this instrument during “H” is displayed, the held
value will be output to it and then be released.
・ The spindle position is being detected while “H” is displayed.
3.2.5 Display value output (when a data processor is connected)
The display value can be output to the data processor.
Press the lower right key in the measurement mode to output the display value to the data
processor.
Refer to "4 Data Output" for cable connections, pin assignment, output format, and timing
chart.
Minimum value detection mode