A044 U/f characteristic
• 00: Constant torque curve
• 01: Reduced torque curve
• 02: User-definable
• 03: SLV control active
• 04: 0 Hz SLV control active
• 05: Vector control with optional DE6-IOM-ENC
module.
00 128
A244 V/f characteristic (second parameter set)
• 00: Constant torque curve
• 01: Reduced torque curve
• 02: User-definable
• 03: SLV control active
• 04: 0 Hz SLV control active
00 128
A234 V/f characteristic (third parameter set)
• 00: Constant torque curve
• 01: Reduced torque curve
• 02: User-definable
00 128
A045 Output voltage [%] 100 128
A051 DC braking
• 00: Inactive
• 01: Active
00 130
A052 DC braking starting frequency [Hz] 0.5 130
A053 DC braking waiting time on deceleration [s] 0.0 130
A054 DC braking torque on deceleration [%] 0 130
A055 DC braking duration on deceleration [s] 0.0 130
A056 Behaviour on activation of the DB input
• 00: Starts on activation of the input, ends after
PNU A055
• 01: Runs as long as input is active
01 130
A057 DC braking torque on acceleration [%] 0 130
A058 DC braking duration on acceleration [s] 0.0 131
A059 DC braking frequency [kHz] 5.0 131
A061 Maximum operating frequency [Hz] 0.00 132
A261 Maximum operating frequency (second parameter set) [Hz] 0.00 132
A062 Minimum operating frequency [Hz] 0.00 132
A262 Minimum operating frequency (second parameter set) [Hz] 0.00 132
A063 1st frequency jump [Hz] 0.00 132
A064 Jump width of the 1st frequency jump [Hz] 0.50 132
A065 Second frequency jump [Hz] 0.00 132
A066 Jump width of the second frequency jump [Hz] 0.50 132
A067 Third frequency jump [Hz] 0.00 132
A068 Jump width of the third frequency jump [Hz] 0.50 132
A069 Acceleration pause waiting frequency [Hz] 0.00 133
A070 Acceleration pause waiting duration [s] 0.00 133
A071 PID control
• 00: Inactive
• 01: Active
00 137
A072 P component of the PID control 1.0 138
PNU Function Units Default Page Setpoint