b090 Permissible relative percentage duty factor for built-in
braking transistor
[%] 0.00 167
b091 Type of motor stop when Off button is pressed
00: Braking/deceleration ramp
01: Free run stop
00 168
b092 Configuration of fan operation
00: Fan always switched on
01: Fan switched on only when motor running
00 168
b095 Enable built-in braking transistor
00: Not enabled
01: Enabled in RUN mode
02: Always enabled
00 167
b096 Voltage threshold for braking transistor [V] 720 167
b098 Selection of PCT or NTC
00: No temperature monitoring
01: PTC
02: NTC
00 82
b099 Resistance threshold for thermistor input [O] 3000 82
b100 User-definable U/f characteristics, frequency
coordinates 1
[Hz] 0 128
b101 User-definable U/f characteristics, voltage
coordinates 1
[V] 0.0 128
b102 User-definable U/f characteristics, frequency
coordinates 2
[Hz] 0 128
b103 User-definable U/f characteristics, voltage
coordinates 2
[V] 0.0 128
b104 User-definable U/f characteristics, frequency
coordinates 3
[Hz] 0 128
b105 User-definable U/f characteristics, voltage
coordinates 3
[V] 0.0 128
b106 User-definable U/f characteristics, frequency
coordinates 4
[Hz] 0 128
b107 User-definable U/f characteristics, voltage
coordinates 4
[V] 0.0 128
b108 User-definable U/f characteristics, frequency
coordinates 5
[Hz] 0 128
b109 User-definable U/f characteristics, voltage
coordinates 5
[V] 0.0 128
b110 User-definable U/f characteristics, frequency
coordinates 6
[Hz] 0 128
b111 User-definable V/f characteristics, voltage
coordinates 6
[V] 0.0 128
b112 User-definable U/f characteristics, frequency
coordinates 7
[Hz] 0 128
b113 User-definable U/f characteristics, voltage
coordinates 7
[V] 0.0 129
b120 Brake control
00: Not active
01: Active
00 170
b121 Brake released confirmation waiting time [s] 0.00 170
b122 Waiting time before acceleration [s] 0.00 170
PNU Function Units Default Page Setpoint