Appendix
01/02 AWB8230-1415GB
208
C011 Digital input 1
• 00: Make contact
• 01: Break contact
00 67
C012 Digital input 2 (values a PNU C011) 00 67
C013 Digital input 3 (values a PNU C011) 00 67
C014 Digital input 4 (values a PNU C011) 00 67
C015 Digital input 5 (values a PNU C011) 00 67
C016 Digital input 6 (values a PNU C011) 00 67
C017 Digital input 7 (values a PNU C011) 00 67
C018 Digital input 8 (values a PNU C011) 00 67
C019 Digital input FW (values a PNU C011) 00 67
C021 Signal on digital output 11
• 00: RUN signal
• 01: FA1, frequency reached
• 02: FA2, frequency exceeded
• 03: OL, overload
• 04: OD, PID deviation exceeded
• 05: AL, fault
• 06: FA3, frequency reached (1)
• 07: OTQ, torque reached (exceeded)
• 08: IP, mains failure, immediate stop
• 09: UV, undervoltage
• 10: TRQ, torque limitation
• 11: ONT, Mains On time exceeded
• 12: RNT, Running time exceeded
• 13: THM, motor thermal overload
• 19: BRK, enable signal for external brake
• 20:BER, brake fault
• 21: ZS, zero frequency
• 22: DSE, speed deviation exceeded
• 23: POK, positioning
• 24: FA4, frequency exceeded (2)
• 25: FA5, frequency reached (2)
• OL2, overload alarm 2
01 101
C022 Signal at digital output 12 (values a PNU C021) 00 101
C023 Signal at digital output 13 (values a PNU C021) 03 101
C024 Signal at digital output 14 (values a PNU C021) 07 101
C025 Signal at digital output 15 (values a PNU C021) 08 101
C026 Signal at relay terminals K11-K12
(values a PNU C021)
05 118
C027 Output, FM output
• 00: Output frequency, PWM signal
• 01: Output current
• 02: Torque, SLV control only
• 03: Output frequency, FM signal
• 04: Output voltage
• 05: Inverter input power
• 06: Thermal load ratio
• 07: Ramp frequency
00 59
PNU Function Units Default Page Setpoint