01/02 AWB8230-1415GB
Overview
55
BOK 44 External brake
enable signal
confirmation
Confirmation of an external motor brake’s Enable signal, for example on lifts, which the DV6
frequency inverter uses to monitor the brake’s operating state.
ORT 45 Direction of rotation
Only with optional DE6-IOM-ENC module
LAC 46 Ramp function off Only with optional DE6-IOM-ENC module
PCLR 47 Erase positioning
deviations
Only with optional DE6-IOM-ENC module
STAT 48 Setpoint definition
through module
Only with optional module
NO no –
No function
Non-programmable digital inputs
FW – FWD = clockwise
operation (start/stop)
Input FW(D) closed: motor starts up clockwise.
Input FW(D) open: controlled motor deceleration from clockwise operation.
FW(D) and REV inputs closed simultaneously: controlled motor deceleration to stop.
P24 – 24 V H for digital inputs
24 V H potential for digital inputs 1 to 8
Frequency setpoint input
h – 10 V setpoint voltage for
external potentiometer
R: 1 to 10 kO
Resolution: 12-bit
O – Analog input for setpoint
frequency through
voltage signal
(0 to 10 V H)
Input impedance: 10 kO
I F 20 mA
Resolution: 12-bit
O2 – Analog input for setpoint
frequency through
voltage signal
(–10 to +10 V H)
Input impedance: 10 kO
I F 20 mA
Resolution: 12-bit
OI – Analog input for setpoint
frequency through
current signal
(4 to 20 mA)
The OI input for a setpoint value from 4 to 20 mA is used only
when the digital input configured as the AT input is closed.
Load resistor: 250 O
Resolution: 12-bit
L – 0 V reference potential
for setpoint inputs
If no digital input is configured as an AT input, the setpoint values O and OI are added together.
Analog outputs
FM – Frequency output You can assign the following variables to outputs AM, AMI and FM:
Output frequency, motor current, torque, output voltage, input power, ramp frequency and
thermal load ratio
AM – Voltage output
(0 to 10 V, 8-bit)
AMI – Current output
(4 to 20 mA, 8-bit)
L – 0V
0 V reference potential for the analog output
Name Value
1)
Function Description
LOIOH
PES
LOIO
–
+
PES
LO2
PES
–10 V...+10 V 0 V
LOI
–
+
PES
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616