B.2 Technical data MSD Servo Drive DC-AC
B.2.1 G392-004 to G393-020 / G397-020 to G397-025
Designation
Technical data
G393-004
G393-006
G393-008
G393-012
G393-016/
G397-020
G393-020/
G397-025
Output motor-side
1)
Voltage 3-phase U
DC
/√2
Rated
current ef-
fective (l
n
)
Air cooling 4A 6A 8A 12A 16A 20A
Liquid cooling - - - - 20A 25A
Peak
current
Air cooling see tables B.1 to B.4
Liquid cooling - - - - tables B.6 to B.9
Rotating field frequency 0 ... 400Hz
Power stage switching frequency 4, 8, 12, 16kHz
DC input
DC voltage (U
DC
) nominal
2)
565V
DC
/ 650V
DC
/ 678V
DC
/ 770V
DC
Current (RMS approximation
value)
1.7·I
Motor
Device connected load
3)
U
ZK
·1.7·I
Motor
Power loss
at I
N
and
8kHz/
565VDC
3)
Air cooling 110W 140W 185W 255W 320W 390W
Liquid cooling - - - - 390W 480W
DC link
Capacity 60µF 105µF 288µF
1) All data referred to output voltage 400 V
eff
and switching frequency 8 kHz
2) Generated from rectified TN system with grounded neutral point and external conductor voltages 3 x 400 V AC, 3 x 460
V AC or 3 x 480 V AC with the approved Moog Servo Drive devices (MSD Servo Drive AC-AC or MSD Power Supply Unit).
Insulation voltage as per EN 61800-5-1, system voltage 277 V, overvoltage category III.
3) Approximate values
Table B.11 Technical data G393-004 to G393-020
B.2.2 G393-024 to G393-060 / G397-026 to G397-070
Designation
Technical data
G393-024/
G397-026
G393-032/
G397-035
G393-045/
G397-053
G393-060/
G397-070
Output motor-side
1)
Voltage 3-phase U
DC
/√2
Rated current ef-
fective (l
n
)
Air cooling 24A 32A 45A 60A
Liquid cooling 26A 35A 53A 70A
Peak current
Air cooling see tables B.1 to B.4 see table B.5
Liquid cooling see tables B.6 to B.9 see table B.10
Rotating field frequency 0 ... 400Hz
Power stage switching frequency 4, 8, 12, 16kHz
DC input
DC voltage (U
DC
) nominal
2)
565V
DC
/ 650V
DC
/ 678V
DC
/ 770V
DC
Current (RMS approximation value) 1.7·I
Motor
Device connected load U
ZK
·1.7·I
Motor
Power loss at
I
N
and 8 kHz/
565VDC
3)
Air cooling 420W 545W 610W 830W
Liquid cooling 455W 595W 690W 930W
DC link
Capacity
Air cooling
504µF
430µF
900µF
Liquid cooling 900µF
1) All data referred to output voltage 400 V
eff
and switching frequency 8 kHz
2) Generated from rectified TN system with grounded neutral point and external conductor voltages 3 x 400 V AC, 3 x 460
V AC or 3 x 480 V AC with the approved Moog Servo Drive devices (MSD Servo Drive AC-AC or MSD Power Supply Unit).
Insulation voltage as per EN 61800-5-1, system voltage 277 V, overvoltage category III.
3) Approximate values
Table B.12 Technical data G393-024 to G396-060