20
Mechanical installation
MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
3.5 Cooling circuit connection
The MSDServoDrive has a capacity of up to 0.5l of coolant depending on the size.
After the disconnection of the connections, liquid may be left in the device and escape
if the device is tipped. We recommend the usage of a self-sealing liquid coupling (not
included in the scope of supply) to prevent the coolant escaping and to make it possible
to disconnect and connect in the lled state.
1
2
3
4
5
Key
1) Liquid connection with 3/8inch female thread
2) Self-sealing quick-release connection with 3/8inch male thread
3) Self-sealing liquid coupling
4) Adapter for hose connection
5) PUR (polyurethane) hose with clip
NOTE:
Items2 to 5 are not included in the scope of supply.
You will nd these in the cooling circuit connection set
(CB37132-001). Please order seperately.
Figure 3.6 Cooling circuit connection (here: Size 7)
NOTE:
It is imperative the ow from the liquid cooling is connected to the connection
correspondingly marked in Figure3.4, Figure3.5 or Figure3.6.