MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
65
Servo drive
Switching
frequency
of the
power
stage
Ambient
temperature
At mains voltage 400 V At mains voltage 460 V At mains voltage 480 V
Overload
factor
≥ 5 Hz
For
time
1)
Rated
current
Peak current
[A
eff
]
Rated
current
Peak current
[A
eff
]
Rated
current
Peak current
[A
eff
]
[kHz] [°C]/[°F] [A
eff
] 0Hz to >5Hz [A
eff
] 0Hz to >5Hz [A
eff
] 0Hz to >5Hz [%] [s]
G392-016 (Size 3)
4
+45
(+113)
16 32 16 32 16 32
200 10
8
+40
(+104)
16 32 13.9 27.8 13.3 26.6
12 11 22 8.8 17.6 8 16
16 8 16 5.9 11.8 5.2 10.4
G392-020 (Size 3)
4
+45
(+113)
20 40 20 40 20 40
200
10
8
+40
(+104)
20 40 17.4 34.8 16.6 33.2
12 13.8 27.6 11 22 10 20
16 10 20 7.4 14.8 6.5 13
G392-024 (Size 4)
4
+45
(+113)
24 48 24 48 24 48
200 10
8
+40
(+104)
24 48 21 42 20 40
12 15.8 31.6 12.4 24.8 11.3 22.6
16 11.3 22.6 9.2 18.4 8.4 16.8
G392-032 (Size 4)
4
+45
(+113)
32 64 32 64 32 64
200
10
8
+40
(+104)
32 64 28 56 26.7 53.4
12 21 42 16.5 33 15 30
16 15 30 12.2 24.4 11.2 22.4
All data apply for a motor cable length ≤10 m (32.80 ft).
1) Shutdown as per I²t characteristic
2) For G392 Size 1-Safety only approved up to +40 °C (+104 °F).
Table A.2 Rated and peak current, Size 1 to Size 4 (air cooling, three-phase)