MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
67
Servo drive
Power
stage
switching
frequency
Ambient
tempera-
ture
At mains voltage 400 V At mains voltage 460 V At mains voltage 480 V
Overload
factor
≥5Hz
For time
1)
Rated
current
Peak current [Aeff]
2)
Rated
current
Peak current [Aeff]
2)
Rated
current
Peak current [Aeff]
2)
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
[kHz] [°C]/[°F] [Aeff] 0 Hz
Up to 5
Hz
>5 Hz [Aeff] 0Hz
Up to 5
Hz
>5 Hz [Aeff] 0 Hz
Up to 5
Hz
>5 Hz [%] [s]
G392-090
(Size 6)
4
+45
(+113)
90 170 180 83 157 166 81 153 162 200
30
8
+40
(+104)
90 134 180 83 124 166 81 121 162 200
12 90 107 144 83 99 133 81 95 130 160
16 72 86 115 67 80 107 65 77 104 160
G392-110
(Size 6)
4
+45
(+113)
110 170 220 102 157 204 99 153 198 200
30
8
+40
(+104)
110 134 165 102 124 153 99 121 149 150
12 90 107 144 83 99 133 81 95 130 160
16 72 86 115 67 80 107 65 77 104 160
G392-143
(Size 6A)
4
+45
(+113)
143 191 286 132 176 264 129 170 258 200
30
8
+40
(+104)
143 152 215 132 140 198 129 136 194 150
12 115 122 173 106 112 159 104 109 156 150
16 92 98 138 85 91 128 83 87 125 150
G392-170
(Size 6A)
4
+45
(+113)
170 191 323 157 176 298 153 170 291 190
10
8
+40
(+104)
170 152 221 157 140 204 153 136 199 130
12 136 122 163 126 112 151 122 109 146 120
16 109 98 131 101 91 121 98 87 118 120
All data apply for a motor cable length ≤10 m (32.80 ft).
1) Shutdown as per I²t characteristic
2) Permissible peak current at maximum 70% initial load
Table A.4 Rated and peak current, Size 6 and Size 6A (air cooling)