4.10.2 Recommended EMI noise lter
P/N Specications Manufacture
M2-EMI10A 250VAC
10A LCR
10ET1 250VAC
10A TYCO
DF300-10A-01 250VAC
10A Dephir
4.10.3 Clamp noise lter for cable
Install noise lters for signal lines to all cables(Power cable, motor cable, encoder cable and I/O signal
cable)
Signal cable
Wind cables the 2-3 turns to form the signal noise lter.
Motor cable
Remove the cables jacket to the length so that wires can be wound
on the clamp noise lter for 2-3 turns. For e󰀨ective noise reduction,
U/V/W should be wound togther, except the PE cable.
Encoder cable
Wind cables the 2-3 turns to form the signal noise lter.
4.10.4 Recommended clamp noise lter
MOONS’ P/N
P/N Manufacture
M2-OP3035 ZCAT3035-1330 TDK