1-4 MTR3000 Base Station/Repeater: Description
1.2.1 Operating Features
The following are the standard features of a MTR3000 model:
• MOTOTRBO Conventional Operation (2-Slot TDMA, 4FSK Modulation)
• Analog Conventional Operation (FM)
• Continuous Duty Cycle Operation over -30°C to +60°C
• Meets or exceeds the following standards:
- TIA603D
-ETSI 086
-ETSI 113
- ETSI TS 102 361-1 Part 1: DMR Air Interface Protocol
- ETSI TS 102 361-2 Part 2: DMR Voice and Generic Services and Facilities
- ETSI TS 102 361-3 Part 3: DMR Packet Data Protocol
• Synthesized Frequency Generation
• Two Female N-type Antenna Connectors (Rx and Tx)
• Ethernet Port (Network)
• Front mounted USB Port (Service)
• Front mounted microphone port
• Front mounted speaker port
• 9 configurable GPIO/GPI ports
• Power for third party controllers (1 Amp)
• 1.5 PPM Frequency Stability (Temperature AND 1-Year Aging) (UHF)
• 0.1 PPM Frequency Stability (Temperature AND 1-Year Aging) (800/900 MHz)
• External Reference Capability
• Wireline Capability
• Switching Power Supply operates from 85–264 VAC (47–63 Hz)
• Multi-Power Source configurable (AC, DC, or AC with Battery Revert)
• Station Diagnostic Tests-Fixed Set of Tests Factory run upon Start-up
• Physical Dimensions: 5.25" H x 19" W x 16.5" D (133 x 483 x 419 mm) 3RU
• Weight: 40 pounds (19 kg) excluding cabinet or other peripheral equipment
Motorola Network Interface:
• IP Site Connect
• Repeater Diagnostics and Control (RDAC)