• SPECIAL FUNCTION CONTROL CODES
CODE
MODE ACTIVATES
•
The
card
supplied with
the
R-2001D
and
the
applique
Enables
automatic
inside the
front-panel
cover
show
the special function
40
DVM
codes.
Table
3-3 lists
the
special function
control
.::.
DVM
ranging
(default~._
codes
grouped
according
to
the first digit
of
the
code
state)
and
then
grouped
by
function
type.
41
DVM
Enables
1.0 V DVM range
• A
master
reset
code
a(zero) causes all function types
42
DVM
Enables
10
V
DVM
range
to revert
to
the
default
states listed in table 3-3.
•
To
obtain
a
CRT
display
of
all activated special
43
DVM
Enables
100V
DVM
range
functions, simultaneously depress
both
keypad cur-
44
DVM
Enables
300V DVM
range
sor
keys twice.
The
screen will
automatically
return
50
Modulation
Meter
Enables
automatic
to
standard
operation
after
10
to
15
seconds.
modulation
ranging
CODE MODE ACTIVATES
(default state)
51
Modulation
Meter
Enables
10
KHz
range
0
Master
Reset Clears all special functions
52
Modulation
Meter
Enables
100
KHz
range
(default
state)
10
Encode/
Decode
Clears all
IX
E/D
special
60
Counter
Auto
counter
resolution
functions (default state)
(default state)
11
Encode/Decode
Baseband
61
Counter
0.1
Hz
resolution
12
Encode/
Decode
Decode
only
62
Counter
1
Hz
resolution
13
Encode/Decode
Encode
Only
63
Counter
10
Hz
resolution
64
Counter
100
Hz
resolution
20
Monitor
Clears all
2X
monitor
65
Counter
1
KHz
resolution
special functions
(default
70 . System
Control
Sets
factory
control
states
state)
(default state)
21
Monitor
Enables 300
Hz
LPFL
71
System
Control
Sets the
current
state
22
Monitor
Enables
3
KHz
LPFL
as the
power-on
state
23
Monitor
Enables 20
KHz
LPFL
72
System
Control
Initiates a system self test
24
Monitor
Enables 5
Hz
HPFL
73
System
Control
Disables the
automatic
25
Monitor
Enables 300
Hz
HPFL
switching to
monitor
mode
if
the
input
signal
is
over
26
Monitor
Enables 3
KHz
HPFL
O.l.W.
30
Frequency
Clears all frequency
3X
74
System
Control
Mutes
speaker
during
GEN
special
functions
(default
77XY System
Control
Sets the last XY in
RF
state)
memory
presets as duplex
31
Frequency
Enables
direct frequency
7700
System
Control
Resets
from
duplex
to
readout
(10
Hz
resolution)
simplex (default state)
32 Frequency
Enables direct frequency
78XYZ
System
Control
Sets deviation
audible
readout
(l
Hz
resolution)
tAo N,
7'i
50
alarm
to
XY.Z
KHz
c
1:1
-I
33XY
Frequency
Enables scan lock from
78000 System
Control
Disables
audible
alarm
XOO
MHz
to
YOO
MHz
(default state)
3300 Frequency
Enables full-band
79
System
Control
Resets nonvolatile
memory
scan
lock
34XY
Frequency
Enables
scan latch
from
99
Software
Version
Shows P
/N
of
resident
XOO
MHz
to
YOO
MHz
software
version
3400
Frequency
Enables
full-band scan
TABLE 3-3. SPECIAL FUNCTION CONTROL CODES
latch
3-7