Technical parameters for heat pump space heaters and heat pump combination heaters
HAS T 070÷140
31
ENGLISH
EN
The data in this manual are not binding and they can be modified by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.
For low temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions.
Model/Version HAST 140 SSN
Air-to-water heat pump: YES
Water-to-water heat pump: NO
Brine-to-water heat pump: NO
Low-temperature heat pump: YES
Equipped with a supplementary heater: NO
Heat pump combination heater: NO
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output Prated 323,19 kW
Seasonal space heating energy
efficiency
ηs 134,09 %
Seasonal coefficient of performance SCOP 3,43 --
T
j
= – 7 °C
Pdh 248,42 kW Tj = – 7 °C
COPd
or PERd
2,89 -- o %
T
j
= + 2 °C
Pdh 313,01 kW Tj = + 2 °C
COPd
or PERd
3,89 -- o %
T
j
= + 7 °C
Pdh 357,39 kW Tj = + 7 °C
COPd
or PERd
4,65 -- o %
T
j
= + 12 °C
Pdh 409,43 kW Tj = + 12 °C
COPd
or PERd
5,57 -- o %
Tj = bivalent
temperature
Pdh 261,03 kW Tj = bivalent temperature
COPd
or PERd
3,08 -- o %
Tj = operation limit
temperature
Pdh 231,18 kW Tj = operation limit temperature
COPd
or PERd
2,61 -- o %
Bivalent
temperature
Tbiv -5 °C
For air-to-water heat pumps:
Operation limit temperature
TOL -10 °C
Degradation co-
efficient
Cdh 0,9
Heating water operating limit
temperature
WTOL 55 °C
Power consumption in modes other than active mode Supplementary heater*
Off mode
P
OFF
0kW
Rated heat output Psup -- kW
Thermostat-off
mode
P
TO
1,33 kW
Standby mode
P
SB
0,02 kW
Type of energy input --
Crankcase heater
mode
P
CK
0,52 kW
Other items
For air-to-water heat pumps: Rated
air flow rate, outdoors
- 33600
m
3
/h
Capacity control
fixed/
variable
fixed
Sound power level,
indoors
L
WA
--
dB(A)
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
---
m
3
/h
Sound power level,
outdoors
L
WA
81,0
Contact details M.T.A. S.p.A. Via Artigianato, 2 - 35026 Conselve (PD) Italy
Parameters are declared with variable water temperature output.