covers the entire setting range.
the setting for the rotational speed
around this axis. In neutral position the
rotational speed is maintained at zero:
The model always points in the same
direction.
The sensitivity setting ranges from
0% ... 100%:
The sensitivity setting ranges from
-100% ... +100%:
Fixval.Sense
With this parameter, a fixed gyro sensitivity is set for each individual flight phase.
Alternatively, a control can be used. If this is preferred, set the sensitivity to OFF
and assign a control to the Gyro control function. Refer to page 101 for more
details regarding controls assignment.
o The following applies to pure Damping gyros: Adjustment range: 0% to +100%
o The following applies to Heading gyros:
Adjustment range for heading-hold: -100% to -1%
Adjustment range for damping: 0% to +100%
Only the value of the activated flight phase can be displayed. When implementing
changes make sure to activate the desired flight phase first.
The next line indicates if a heading gyro operates in Damping or Heading mode.
If the sensitivity parameter is set to OFF and a control is assigned to the "Gyro"
control function, the value supplied by this control and the respective identifier (<E)
are displayed next to it on the right. If no control is assigned, nothing is displayed
and the sensitivity setting is zero.